HomeIncidents
Data API

AI API outages on October 29, 2026

UTC day · measured every 5 minutes from 4 regions · method

On October 29, 2026 (UTC) our probes attributed 10 outage(s) to 2 provider(s): Gemini API (Google): 9; targon API: 1.

This page is history. Is it down right now?

Live status, updated every 30 minutes: Gemini API (Google), targon API, SambaNova API · all AI APIs, last 72 hours

Was the Gemini API (Google) down on October 29, 2026?

Yes, measured. 9 outage(s) attributed to Google: requests to gemini-flash-lite-latest failed from up to 4 of 4 regions at once while no other provider was failing, first at 13:22 UTC, at least 24 minutes observed in total. At least once Google’s own host answered with an HTTP 5xx.

UTCWhat failedRegionsDurationFailed probesVerdictError
13:02–13:05requests to gemini-flash-lite-latest3 of 4: Asia (Tokyo), Europe (Germany), US (Central)≥3 min3shared with 1 other provider(s) — not attributedtimeout
13:22–13:25requests to gemini-flash-lite-latest3 of 4: Europe (Germany), South America (São Paulo), US (Central)≥3 min3provider outagetimeout
13:42–13:45requests to gemini-flash-lite-latest4 of 4: Asia (Tokyo), Europe (Germany), South America (São Paulo), US (Central)≥3 min4shared with 2 other provider(s) — not attributedtimeout
14:02–14:05requests to gemini-flash-lite-latest3 of 4: Asia (Tokyo), Europe (Germany), South America (São Paulo)≥3 min3shared with 1 other provider(s) — not attributedhttp 503; timeout
14:22–14:25requests to gemini-flash-lite-latest4 of 4: Asia (Tokyo), Europe (Germany), South America (São Paulo), US (Central)≥3 min4shared with 1 other provider(s) — not attributedtimeout
14:42–14:45requests to gemini-flash-lite-latest4 of 4: Asia (Tokyo), Europe (Germany), South America (São Paulo), US (Central)≥3 min4shared with 1 other provider(s) — not attributedtimeout
15:02–15:05requests to gemini-flash-lite-latest4 of 4: Asia (Tokyo), Europe (Germany), South America (São Paulo), US (Central)≥3 min4provider outagetimeout
15:22–15:25requests to gemini-flash-lite-latest4 of 4: Asia (Tokyo), Europe (Germany), South America (São Paulo), US (Central)≥3 min4provider outagetimeout
15:42–15:45requests to gemini-flash-lite-latest4 of 4: Asia (Tokyo), Europe (Germany), South America (São Paulo), US (Central)≥3 min4provider outagehttp 503; timeout
16:02–16:05requests to gemini-flash-lite-latest4 of 4: Asia (Tokyo), Europe (Germany), South America (São Paulo), US (Central)≥3 min4shared with 1 other provider(s) — not attributedhttp 503; timeout
16:22–16:25requests to gemini-flash-lite-latest4 of 4: Asia (Tokyo), Europe (Germany), South America (São Paulo), US (Central)≥3 min4provider outagetimeout
16:42–16:45requests to gemini-flash-lite-latest4 of 4: Asia (Tokyo), Europe (Germany), South America (São Paulo), US (Central)≥3 min4provider outagetimeout
17:02–17:05requests to gemini-flash-lite-latest4 of 4: Asia (Tokyo), Europe (Germany), South America (São Paulo), US (Central)≥3 min4provider outagetimeout
17:22–17:25requests to gemini-flash-lite-latest2 of 4: Asia (Tokyo), Europe (Germany)≥3 min2provider outagetimeout
17:42–17:45requests to gemini-flash-lite-latest3 of 4: Asia (Tokyo), Europe (Germany), US (Central)≥3 min3provider outagetimeout
18:02–18:05requests to gemini-flash-lite-latest4 of 4: Asia (Tokyo), Europe (Germany), South America (São Paulo), US (Central)≥3 min4shared with 1 other provider(s) — not attributedtimeout

Current Gemini API (Google) status

Was the targon API down on October 29, 2026?

Yes, measured. 1 outage(s) attributed to targon: host probes failed from up to 2 of 4 regions at once while no other provider was failing, first at 23:25 UTC, each shorter than one 5-minute probe cycle. At least once targon’s own host answered with an HTTP 5xx.

UTCWhat failedRegionsDurationFailed probesVerdictError
23:25–23:25host probes2 of 4: South America (São Paulo), US (Central)<5 min2provider outagehttp 503

Current targon API status

Was the SambaNova API down on October 29, 2026?

Not attributably. 1 multi-region failure(s) of SambaNova coincided with failures of other providers, so the cause sat above SambaNova and is not blamed on it. SambaNova’s status page lists nothing that day.

UTCWhat failedRegionsDurationFailed probesVerdictError
06:15–06:15host probes2 of 4: South America (São Paulo), US (Central)<5 min2shared with 1 other provider(s) — not attributedtimeout

Current SambaNova API status

51 single-region failure(s) were also recorded that day (yi-01ai 26, google 7, baichuan 3, doubao 2, sambanova 2, sensenova 2, targon 1, nebius 1, stepfun 1, iflytek 1). A failure seen from one region cannot be separated from a problem on that network path, so none of them is called an outage.

How is an outage told apart from a network problem?

Each provider is probed every five minutes from 4 independent regions. A failure is attributed to the provider only when it is seen from two or more regions at once and no other provider fails in the same minutes; a failure shared with other providers has a cause above all of them and is not blamed on anyone. Durations are lower bounds: we see the first and last failed probe, not the real start and end. Status-page entries are the provider’s own words, shown next to the measurement, not instead of it.

· Last 72 hours

Machine-readable: incidents.json · Licence: CC BY 4.0